5 -  21 
5. OPERATION 
  
(c) Temporary stop/restart 
When RYn7 is turned ON during automatic operation, the motor is decelerated to a temporary stop at 
the deceleration time constant in the point table being executed. When RYn7 is turned ON again, the 
remaining distance is executed. 
If the forward/reverse rotation start signal (RYn1 or RYn2) is ignored if it is switched on during a 
temporary stop. 
The remaining moving distance is cleared when the operation mode is changed from the automatic 
mode to the manual mode during a temporary stop. 
The temporary stop/restart input is ignored during zeroing and jog operation. 
1) When the servo motor is rotating 
ON
OFF
ON
OFF
ON
OFF
0r/min
OFF
OFF
ON
ON
OFF
ON
Forward
rotation
Servo motor speed
Point table
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Temporary stop/Restart (RYn7)
Temporary stop (RXn7)
Rough match (RXn2)
In position (RXn1)
Remaining
distance
Point table No. out put
(RX(n+2)2 to RX(n+2)9)
No.n
Acceleration time constant 
of point table No.n
Deceleration time constant 
of point table No.n
No.n
Movement completion (RXnC)
 
2) During dwell 
Dwell    ta   tb
ON
OFF
ON
OFF
ON
OFF
0r/min
OFF
OFF
ON
ON
ta
tb
OFF
ON
Forward
rotation
Servo motor speed
Point table
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Temporary stop/Restart (RYn7)
Temporary stop (RXn7)
Rough match (RXn2)
In position (RXn1)
No.n
Point table No. out put
(RX(n+2)2 to RX(n+2)9)
Point table No.n
Point table No.n   1
No.n
Movement completion (RXnC)