5. OPERATION 
 
5.4.3 Remote register-based position/speed setting 
This operation can be used when 2 stations are occupied. This section explains operation to be performed 
when the remote register is used to specify the position command data/speed command data. 
 
(1) Absolute value command positioning in absolute value command system 
The position data set in the absolute value command system are used as absolute values in positioning. 
Set the input devices and parameters as indicated below. 
 
Item Used 
device/parameter 
Description 
Automatic operation mode 
Automatic/manual selection (RYn6) 
Turn RYn6 ON. 
Remote register-based position/speed 
setting 
Position/speed specifying system selection 
(RY(n 2)A) 
Turn RY(n 2)A ON. 
Command system 
Parameter No.PA01 
0 : Absolute value command 
system is selected. 
Remote register-based position/speed 
specifying system selection 
Parameter No.PC30 
2 : Remote register-based 
position/speed specifying 
system is selected. In the 
case, always set an 
acceleration/deceleration 
time constant in the point 
table No.1. 
Position command data lower 16 bit 
(RWwn 4) 
Position data 
Position command data upper 16 bit 
(RWwn 5) 
Set the lower 16 bits of position data 
to RWwn 4, and the upper 16 bits 
to RWwn 5. 
Setting range:  999999 to 999999 
Servo motor speed 
Speed command data (RWwn 6) 
Set the servo motor speed. 
 
Set the position data to RWwn 4/RWwn 5, and the speed command data to RWwn 6, and store them 
into the servo amplifier. 
In the absolute value command system, Absolute value/incremental value selection (RY(n 2)B) can be 
used to select whether the values set to the position data are absolute values or incremental values. The 
position data set to RWwn 4/RWwn 5 are handled as absolute values when RY(n 2)B is turned OFF or 
as incremental values when it is turned ON. During operation, how the position data will be handled 
(absolute values or incremental values) depends on the status of RY(n 2)B when Forward rotation start 
(RYn1) is turned ON. 