6 -  21 
6. PARAMETERS 
 
No.  Symbol 
Name and function 
Initial value 
Unit 
PC49 
0000h 
PC50 
 
For manufacturer setting 
0000h 
 
 
6.3.2 Detail list 
No.  Symbol 
Name and function 
Initial value 
Unit 
Setting range
PC01 
 
For manufacturer setting 
Do not change this value by any means. 
0000h  
 
PC02 *ZTY 
 
Home position return type 
Used to set the home position return system. (Refer to section 5.6.) 
Home position return system
0: Dog type
1: Count type
2: Data setting type
3: Stopper type
4: Home position ignorance
    (Servo-on position as home position)
5: Dog type rear end reference
6: Count type front end reference
7: Dog cradle type
8: Dog type right-before Z-phase reference
9: Dog type front end reference
A: Dogless Z-phase reference
0 0 0
 
0000h  
Refer 
to 
name and 
function 
column. 
PC03 *ZDIR 
 
Home position return direction 
Used to set the home position return direction. 
Home position return direction
0: Address increment direction
1: Address decrement direction
0 0 0
 
0001h  Refer 
to 
name and 
function 
column. 
PC04 ZRF 
 
Home position return speed 
Used to set the servo motor speed for home position return. 
(Refer to section 5.6.) 
500 r/min  0 to 
permissible 
speed 
PC05 CRF 
 
Creep speed 
Used to set the creep speed after proximity dog detection. 
(Refer to section 5.6.) 
10 r/min  0 to 
permissible 
speed 
PC06 
ZST 
Home position shift distance 
Used to set the shift distance starting at the Z-phase pulse detection position 
inside the encoder. (Refer to section 5.6.) 
m 0 
to 
65535 
PC07  *ZPS  Home position return position data 
Used to set the current position on completion of home position return. 
(Refer to section 5.6.) 
10
STM
32768 
to 
32767 
PC08 
DCT  Moving distance after proximity dog 
Used to set the moving distance after proximity dog in count type home 
position return. (Refer to section 5.6.) 
1000 
10
STM
m 0 
 
to 
65535 
PC09 
ZTM  Stopper type home position return stopper time 
In stopper type home position return, used to set the time from when the 
machine part is pressed against the stopper and the torque limit set in 
parameter No.PC10 is reached to when the home position is set. 
(Refer to section 5.6.5.) 
100 ms  5 
to 
1000