Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
10 -  4 
10. SPECIAL ADJUSTMENT FUNCTIONS 
 
POINT 
 
"Filter OFF" enables a return to the factory-set initial value. 
When adaptive tuning is executed, vibration sound increases as an excitation 
signal is forcibly applied for several seconds. 
When adaptive tuning is executed, machine resonance is detected for a 
maximum of 10 seconds and a filter is generated. After filter generation, the 
adaptive tuning mode automatically shifts to the manual mode. 
Adaptive tuning generates the optimum filter with the currently set control 
gains. If vibration occurs when the response setting is increased, execute 
adaptive tuning again. 
 During adaptive tuning, a filter having the best notch depth at the set control 
gain is generated. To allow a filter margin against machine resonance, 
increase the notch depth in the manual mode. 
 
10.3 Machine resonance suppression filter 
(1) Function 
The machine resonance suppression filter is a filter function (notch filter) which decreases the gain of the 
specific frequency to suppress the resonance of the mechanical system. You can set the gain decreasing 
frequency (notch frequency), gain decreasing depth and width. 
Mechanical 
system 
response
level
Machine resonance point
Frequency
Notch 
depth
Notch frequency
Frequency
Notch width
Notch depth
 
You can use the machine resonance suppression filter 1 (parameter No.PB13, PB14) and machine 
resonance suppression filter 2 (parameter No.PB15, PB16) to suppress the vibration of two resonance 
frequencies. Execution of adaptive tuning in the filter tuning mode automatically adjusts the machine 
resonance suppression filter. When adaptive tuning is ON, the adaptive tuning mode shifts to the manual 
mode after the predetermined period of time. The manual mode enables manual setting using the machine 
resonance suppression filter 1. 
Mechanical 
system 
response
level
Machine resonance point
Frequency
Notch 
depth
Frequency
Parameter No.PB01, 
PB13, PB14
Parameter No.PB15, 
PB16