Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
10 -  6 
10. SPECIAL ADJUSTMENT FUNCTIONS 
 
10.4 Advanced vibration suppression control 
(1) Operation 
Vibration suppression control is used to further suppress machine side vibration, such as workpiece end 
vibration and base shake. The motor side operation is adjusted for positioning so that the machine does not 
shake. 
Vibration suppression control OFF
(Nomal control)
Motor side
Machine side
t
Vibration suppression control ON
t
Po
si
tio
n
Po
si
tio
n
Motor side
Machine side
 
When the advanced vibration suppression control (vibration suppression control tuning mode parameter 
No.PB02) is executed, the vibration frequency at machine side can automatically be estimated to suppress 
machine side vibration. 
In the vibration suppression control tuning mode, this mode shifts to the manual mode after operation is 
performed the predetermined number of times. The manual mode enables manual setting using the 
vibration suppression control vibration frequency setting (parameter No.PB19) and vibration suppression 
control resonance frequency setting (parameter No.PB20). 
 
(2) Parameter 
Select the operation of the vibration suppression control tuning mode (parameter No.PB02). 
0 0 0
Vibration suppression control 
tuning mode
Parameter No.PB02
 
Setting 
Vibration suppression control tuning mode 
Automatically set parameter 
Vibration suppression control OFF 
(Note) 
Vibration suppression control tuning mode 
(Advanced vibration suppression control) 
Parameter No.PB19 
Parameter No.PB20 
2 Manual 
mode 
 
Note. Parameter No.PB19 and PB20 are fixed to the initial values. 
 
POINT 
 
The function is made valid when the auto tuning mode (parameter No.PA08) 
is the auto tuning mode 2 ("0002") or manual mode ("0003"). 
The machine resonance frequency supported in the vibration suppression 
control tuning mode is 1.0Hz to 100.0Hz. The function is not effective for 
vibration outside this range. 
Stop the motor before changing the vibration suppression control-related 
parameters (parameter No.PB02, PB19, PB20, PB33, PB34). A failure to do 
so will cause a shock. 
For positioning operation during execution of vibration suppression control 
tuning, provide a stop time to ensure a stop after full vibration damping. 
Vibration suppression control tuning may not make normal estimation if the 
residual vibration at the motor side is small. 
Vibration suppression control tuning sets the optimum parameter with the 
currently set control gains. When the response setting is increased, set 