14. OPTIONS AND AUXILIARY EQUIPMENT 
 
(6) Specifications 
 
Power regeneration common converter
FR-CV-
Item 
7.5K 11K 15K 22K 30K 37K 55K 
Total of connectable servo amplifier capacities    [kW] 
3.75 
5.5 
7.5 
11 
15 
18.5 
27.5 
Maximum servo amplifier capacity                        [kW] 
3.5 
11 
15 
15 
22 
Total of connectable servo motor 
rated currents                              [A] 
33 46 61 90 115 145 
215 
Short-time 
rating 
Total capacity of applicable servo motors, 300% torque, 60s (Note 1) 
Output 
Regenerative 
braking torque 
Continuous 
rating 
100% torque 
Rated input AC voltage/frequency 
Three-phase 200 to 220V 50Hz, 200 to 230V 60Hz 
Permissible AC voltage fluctuation 
Three-phase 170 to 242V 50Hz, 170 to 253V 60Hz 
Permissible frequency fluctuation 
5% 
Power supply  
Power 
supply 
capacity 
(Note 
2) 
[kVA] 
17 20 28 41 52 66 100 
Protective structure (JEM 1030), cooling system 
Open type (IP00), forced cooling 
Ambient temperature 
-10  to +50  (14 to 122 ) (non-freezing) 
Ambient humidity 
90%RH or less (non-condensing) 
Environment 
Ambience 
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt) 
Altitude, vibration 
1000m or less above sea level, 5.9m/s
2
 or less 
No-fuse breaker or leakage current breaker 
30AF 
30A 
50AF 
50A 
100AF 
75A 
100AF 
100A 
225AF 
125A 
225AF 
125A 
225AF 
175A 
Magnetic 
contactor 
S-N20 S-N35 S-N50 S-N65 S-N95 S-N95 S-N125 
 
Power regeneration common converter
FR-CV-H
Item 
22K 30K 37K 55K 
Total of connectable servo amplifier capacities    [kW] 
11 
15 
18.5 
27.5 
Maximum servo amplifier capacity                        [kW] 
11 
15 
15 
22 
Total of connectable servo motor 
rated currents                              [A] 
43 57 71 110 
Short-time 
rating 
Total capacity of applicable servo motors, 300% 
torque, 60s (Note1) 
Output 
Regenerative 
braking torque 
Continuous 
rating 
100% torque 
Rated input AC voltage/frequency 
Three-phase 380 to 480V, 50Hz/60Hz 
Permissible AC voltage fluctuation 
Three-phase 323 to 528V, 50Hz/60Hz 
Permissible frequency fluctuation 
5% 
Power supply  
Power supply capacity            [kVA] 
41 
52 
66 
100 
Protective structure (JEM 1030), cooling system 
Open type (IP00), forced cooling 
Ambient temperature 
-10  to +50  (14 to 122 ) (non-freezing) 
Ambient humidity 
90%RH or less (non-condensing) 
Environment 
Ambience 
Indoors (without corrosive gas, flammable gas, oil 
mist, dust and dirt) 
Altitude, vibration 
1000m or less above sea level, 5.9m/s
2
 or less 
No-fuse breaker or leakage current breaker 
60AF 
60A 
100AF 
175A 
100AF 
175A 
225AF 
125A 
Magnetic contactor 
S-N25 
S-N35 
S-N35 
S-N65 
Note 1. This is the time when the protective function of the FR-CV is activated. The protective function of the servo amplifier is activated 
in the time indicated in section 13.1. 
2. When connecting the capacity of connectable servo amplifier, specify the value of servo amplifier.