14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.6 External dynamic brake 
POINT 
 
Configure up a sequence which switches off the contact of the brake unit after 
(or as soon as) it has turned off the servo on signal at a power failure or 
failure. 
 For the braking time taken when the dynamic brake is operated, refer to 
section 13.3. 
 The brake unit is rated for a short duration. Do not use it for high duty. 
 When using the 400V class dynamic brake, the power supply voltage is 
restricted to 1-phase 380VAC to 463VAC (50Hz/60Hz). 
 
(1) Selection of dynamic brake 
The dynamic brake is designed to bring the servo motor to a sudden stop when a power failure occurs 
or the protective circuit is activated, and is built in the 7kW or less servo amplifier. Since it is not built 
in the 11kW or more servo amplifier, purchase it separately if required. Assign the dynamic brake interlock 
(DB) to any of CN6-14, CN6-15, and CN6-16 pins in parameter No.PD09, PD10 or PD11. 
 
Servo amplifier 
Dynamic brake 
MR-J3-11KT DBU-11K 
MR-J3-15KT DBU-15K 
MR-J3-22KT DBU-22K 
MR-J3-11KT4 DBU-11K-4 
MR-J3-15KT4 
MR-J3-22KT4 
DBU-22K-4