Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
14 -  73 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.13 Relays (recommended) 
The following relays should be used with the interfaces. 
 
Interface Selection 
example 
Relay used for digital input command signals (interface DI-1) To prevent defective contacts , use a relay for small signal 
(twin contacts). 
(Ex.) Omron : type G2A , MY 
Relay used for digital output signals (interface DO-1) 
Small relay with 12VDC or 24VDC of rated current 40mA or 
less 
(Ex.) Omron : type MY 
 
14.14 Surge absorbers (recommended) 
A surge absorber is required for the electromagnetic brake. Use the following surge absorber or equivalent. 
When using the surge absorber, perform insulation beforehand to prevent short-circuit. 
 
Maximum rating 
Permissible circuit 
voltage 
Surge 
immunity 
Energy 
immunity 
Rated 
power 
Maximum 
limit voltage 
Static 
capacity 
(reference 
value) 
Varistor voltage 
rating (range) V1mA 
AC [Vma] 
DC [V] 
[A] 
[J] 
[W] 
[A] 
[V] 
[pF] 
[V] 
140 180 
(Note) 
500/time 
5 0.4 
25 
360 
300 
220 
(198 to 242) 
Note. 1 time   8   20 s 
 
13.5
1
6.
3.
or
 le
ss
3
0.
or
 m
or
e
4.7  1.0
  0.8 
 
[Unit: mm] 
 
(Example)  ERZV10D221 (Matsushita Electric Industry) 
TNR-10V221K (Nippon chemi-con)  
Outline drawing [mm] (ERZ-C10DK221)