Справочник Пользователя для Mitsubishi Electronics MR-J2M-P8B

Скачать
Страница из 195
5 -  20
5. PARAMETERS
Classifi-
cation
No.
Symbol
Name and Function
Initial
Value
Unit
Setting
Range
11
*SL1
Slot 1 axis number selection
Choose the axis number of the drive unit connected to the first slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the first axis is set to the first slot.
0000
0000
to
0007h
12
*SL2
Slot 2 axis number selection
Choose the axis number of the drive unit connected to the second
slot of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the second axis is set to the second slot.
0001
0000
to
0007h
13
*SL3
Slot 3 axis number selection
Choose the axis number of the drive unit connected to the third slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the third axis is set to the third slot.
0002
0000
to
0007h
14
*SL4
Slot 4 axis number selection
Choose the axis number of the drive unit connected to the fourth slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the fourth axis is set to the fourth slot.
0003
0000
to
0007h
15
*SL5
Slot 5 axis number selection
Choose the axis number of the drive unit connected to the fifth slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the fifth axis is set to the fifth slot.
0004
0000
to
0007h
16
*SL6
Slot 6 axis number selection
Choose the axis number of the drive unit connected to the sixth slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the sixth axis is set to the sixth slot.
0005
0000
to
0007h
17
*SL7
Slot 7 axis number selection
Choose the axis number of the drive unit connected to the seventh
slot of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the seventh axis is set to the seventh slot.
0006
0000
to
0007h
18
*SL8
Slot 8 axis number selection
Choose the axis number of the drive unit connected to the eighth slot
of the base unit. (Refer to Section 2.8)
Axis number   set value   1
In the initial setting, the eighth axis is set to the eighth slot.
0007
0000
to
0007h
IFU parameter write inhibit
Setting
Setting
operation
Operation from unit operation section or
MR Configurator
(servo configuration software)
Reference
0000
(initial
value)
Write
IFU parameter No. 1 to 19
Reference
000A
Write
IFU parameter No. 19
Basic IFU 
param
eters
19
*BLK
0000
Refer to
name
and
function
column.