DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install Management Terminal and Activate System 
Page 3-13
Set Country Options 
3
5. If all red LEDs do not go off, reseat (unplug and reinsert) any 
purple
-labeled circuit packs displaying red LEDs.
!
CAUTION:
To avoid a disk crash, never reset the DEFINITY AUDIX System 
without first shutting it down. Shut down the DEFINITY AUDIX System 
(and allow the disk to completely spin down) before unplugging the 
assembly. See 
 
for the proper procedures.
6. If the red LEDs still do not go off, refer to 
DEFINITY Enterprise 
Communications Server Release 6 Maintenance for R6r
, or to 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance for R6vs/si
.
NOTE:
Ignore the red alarm indication LED on the TN767 or TN464 DS1 
circuit pack until after the DS1 circuit pack is administered. Alarms 
will appear in the Alarm Log when power is applied to the system 
before all equipment connecting to port circuit packs is installed. 
Normally, some alarms will be logged when power is applied to the 
system, but should be resolved quickly. If no equipment is 
connected to the port circuit packs, alarms associated with these 
ports can take up to four hours to log, but will clear automatically 
after all equipment is installed and operating correctly.
Table 3-1.
Country Codes
Country Code
Country
Code
USA
1
France
12
Australia
2
Germany
13
Japan
3
Czechoslovakia
14
Italy
4
Russia
15
The Netherlands
5
Argentina
16
Singapore
6
Greece
17
Mexico
7
China
18
Belgium
8
Hong Kong
19
Saudi Arabia
9
Thailand
20
United Kingdom
10
Macedonia
21
Spain
11