Справочник Пользователя для Pelco IS20CHV10S

Скачать
Страница из 28
C3472M-C (9/10)
13
MOUNTING THE CAMERA
The mounting requirements are shown as follows:
*Make sure that the installed mount bracket can support more than five times the weight of the camera.
USING A 2-GANG JUNCTION BOX
1. Install the 2-gang junction box (not supplied) onto the wall/ceiling. 
a.
When using a 2-gang junction box (4 x 4 inches), procure one locally that meets the dimensions in 
Figure 6.
b.
Locally procure four camera mounting screws suitable for the installation surface and structure of the 
wall/ceiling or 2-gang junction box.
2. Mount the camera onto the 2-gang junction box with four screws (not supplied). 
3. Fasten all of the mounting screws (refer to Figure 6).
Figure 6. Mounting the Camera to a 2-Gang Junction Box
Mounting 
Site
Model
Recommended Screw and 
Tightening Torque
Number of 
Screws
Minimum Pullout 
Strength 
Ceiling/wall
Two-gang junction 
box
M4 (or appropriate),
1.6 N·m (16 kgf·cm)
4 pcs.
196 N/pc.(20 kgf/pc.)
Ceiling/wall
Surface mount
M4 (or appropriate),
1.6 N·m (16 kgf·cm)
4 pcs.
196 N/pc.(20 kgf/pc.)
Ceiling
Flush mount
*
ì
46 mm (1.81 inches)
î
83.5 mm (3.27 inches)