SURFACE MOUNTING 
1. Prepare the mounting space.
If the camera is directly mounted on a wall/ceiling, align the camera mounting position with the 
position of the hole through which the cables are routed, and then make the hole.
If no hole is made through a wall/ceiling and open wiring along a wall/ceiling is used, remove the dust 
guard cap, take out the cable, replace the dust guard cap, and then process the cover so that the 
cables can be routed through the side of the cover.
2. Place the camera onto the wall/ceiling and mark four screw positions with a pen.
3. Mount the camera onto the wall/ceiling with the four screws (not supplied). 
4. Fasten all of the mounting screws. 
FLUSH MOUNTING
1. Using the supplied template, prepare a mounting hole that is 160 mm (6.29 inches) in diameter.
2. Position two of the spring hooks of the camera (refer to Figure 7).
When the ceiling mount bracket is installed after positioning the spring hooks in the opposite side, they may 
become difficult to pull out.
Figure 7. Positioning the Spring Hooks
WARNING: Be careful when preparing the mounting hole. If the mounting hole is too large, the 
ceiling mount bracket cannot be mounted securely.
ì
Main Body
î
Spring Hook