VOYAGEUR GRAND Wood Insert
R
6
Getting Started
Installer’s Guide
A. Design and Installation Considerations
2. Prior to installing, determine the following:
•  Type of chimney connector to be used
  · single wall, 6 inch (152mm) diameter, stainless steel, 
or
  · double wall, 6 inch (152mm) diameter, stainless steel
•  Consult
pages 31 and 32 for clearances to combustibles
•  Power outlet located close by for optional blower
Draft is the pressure difference needed to vent appliances 
successfully. When a appliance is drafting successfully, all 
combustion byproducts are exiting the home through the 
chimney.
Considerations for successful draft include:
•  Preventing negative pressure
•  Location of appliance and chimney
To be sure that your appliance burns properly:
•  During a low burn, the chimney draft (static pressure) should 
be approximately -.04 inch water column (W.C.)
•  During a high burn the chimney draft should be approximately
-.10 inch (W.C.)
•  Measure the W.C at 6 inches (152mm) above the top of the
appliance after one hour of operation at each burn setting.
NOTICE:  Hearth  &  Home  Technologies  assumes  no
responsibility for the improper performance of the appliance 
system caused by:
B. Draft
Check building codes prior to installation.
•  Installation  MUST  comply  with  local,  regional,  state  and
national codes and regulations.
•  Consult  insurance  carrier,  local  building,  fire  officials  or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
CAUTION
WARNING
•  DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVICING ANOTHER APPLIANCE.
•  DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow flue gases to enter the house.
Asphyxiation Risk.
•  Installation and use of any damaged appliance.
•  Modification of the appliance.
•  Installation  other  than  as  instructed  by  Hearth  &  Home
Technologies.
•  Installation and/or use of any component part not approved
by Hearth & Home Technologies.
•  Operating  appliance  without  fully  assembling  all
components.
•  Operating appliance without legs attached (if supplied with
unit).
•  Do NOT Overfire - If appliance or chimney connector glows,
you are overfiring.
Any such action that may cause a fire hazard.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be 
voided by, the following actions:
•  Inadequate draft due to environmental conditions
•  Downdrafts
•  Tight sealing construction of the structure
•  Mechanical exhausting devices
•  Overdrafting caused by excessive chimney heights
•  Ideal performance is with height of chimney between
14-16 feet (4.26-4.88m) measured from the base of 
the appliance.
Quadra-Fire wood inserts are designed for factory-built non-
combustible  fireplaces  that  have  been  installed  in  accor-
dance with the National, Provincial, State and local building
codes.
1. Prior to installing the wood insert:
•  Have the chimney and adjacent structure inspected and
cleaned by qualified professionals. Heart & Home Tech-
nologies recommends that NFI or CSIA certified profes-
sionals,  or  technicians  under  the  direction  of  certified
professionals, conduct a minmum of a NFPA 211 Level 2
inspection of the chimney.
•  Replace component parts of the chimney and fireplace
as specified by the professionals.
•  Ensure all joints are properly engaged and the chimney is
properly secured.