Figure 27.1
E.  Chimney Termination Requirements
Follow manufacturer’s instructions for clearance, securing
flashing and terminating the chimney.
   
Must have an approved and Listed cap
 
 
Must not be located where it will become plugged by 
snow or other material
•  Must terminate at least 3 feet (91cm) above the roof
and at least 2 feet (61cm) above any portion of the 
roof within 10 feet (305cm).
•  Must be located away from trees or other structures
D.  Locating Your Stove & Chimney
Location of the appliance and chimney will affect perfor-
mance. As shown in
Figure 27.1 the chimney should:
 •  Install through the warm space enclosed by the build-
ing envelope. This helps to produce more draft, espe-
cially during lighting and die down of the fire.
 •  Penetrate the highest part of the roof. This minimizes
the affects of wind turbulence and down drafts.
 •  Consider  the  appliance  location  in  order  to  avoid
floor and ceiling attic joists and rafters.
 •
Locate  termination  cap  away  from  trees,  adjacent
structures, uneven roof lines and other obstruc-
tions.
Your local dealer is the expert in your geographic area and
can usually make suggestions or discover solutions that will
easily correct your flue problem.
NOTICE:
•  Chimney performance may vary.
•  Trees, buildings, roof lines and wind conditions affect
performance.
•  Chimney height may need adjustment if smoking or
overdraft occurs.
NOTICE:  Locating the appliance in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near
•  Frequently open doors
•  Central heat outlets or returns