VOYAGEUR GRAND Wood Insert
F.  Prefabricated Metal Chimney
E.  Metal Heat Circulating Masonry
The chimney can be new or existing, masonry or prefabricated
and must meet the following minimum requirements:
 • Must be minimum 6 inch (152mm) inside diameter of
high temperature chimney listed to UL 103 HT (2100
o
F)
or ULC S628.
 • Must use components required by the manufacturer for
installation.
 • Must maintain clearances required by the manufacturer
for installation.
 • Refer to manufacturers instructions for installation
 •This  insert  is  listed  to  UL  1482  Standard  and  is
approved for installation into listed factory-built solid 
fuel fireplaces listed to UL 127 conforming to the follow-
ing specifications and instructions:
 •The  original  factory-built  clearance  fireplace  chimney
cap must be re-installed after installing the approved 
chimney  liner  meeting  type  UL  103  HT  requirements
(2100°F) per UL 1777.
 
•The  liner  must  be  securely  attached  to  the  insert  flue
collar and the chimney top. 
 •The  air  flow  of  the  factory-built  solid  fuel  fireplace
system must not be altered. The flue liner top support
attachment must not reduce the air flow for the existing
air-cooled chimney system.
 •No dilution air is allowed to enter the chimney.
   1. 
Secure the fireplace damper in the open position.
If this cannot be accomplished, it will be necessary 
to remove the damper.
   2. Seal  damper  area  of  chimney  around  chimney
connector with a high temperature sealant or seal 
insert against the face of the fireplace.
    3. Both methods must be removable and replaceable 
for cleaning and re-installation.
This insert conforms with the safety standard UL-1482 and
ULC S628 (Canada) in all respects and is approved to UL &
ULC safety standards for installation and use within a fire-
place with masonry chimney, in accordance with NFPA 211,
and CAN/CSA-B365-01.
Minimum Width of Cavity Opening - Front
32-7/8*
835
Minimum Width of Cavity Opening - Rear
24*
610
Minimum Height
24*
610
Minimum Depth from Front to Rear
18*
457
Inches
Millimeters
Fire Risk.
When lining air-cooled factory-built chimneys:.
•  Run chimney liner approved to UL 1777 Type
HT requirements (2100 degrees F)
•  Re-install original factory built chimney cap
ONLY
•  DO NOT block cooling air openings in chimney
•  Blocking cooling air will overheat the chimney
WARNING
NOTICE: In Canada when using a factory-built chimney it must
be safety listed,
 Type UL103 HT (2100oF) [1149oC] CLASS 
“A” or conforming to CAN/ULC-S629M, STANDARD FOR 
650
o
C FACTORY-BUILT CHIMNEYS.
NOTE:  Refer to chimney liner manufacturer for recom-
mendations  on  supporting  the  liner.    Installation  into 
fireplaces without a permit will void the listing.
WARNING! Risk of Fire!
Follow  venting  manufacturer’s  clearances  and
instructions when installing venting system.
To  maintain  the  functionality  of  the  fireplace’s  chimney
system  you  may  use  a  Simpson  Dura-Vent  DuraLiner
Slip Hanger, Part # 4671, and attach to the bottom of the
fireplace chimney cap to support the liner. You have two
options to completing the installation.
Option one - Not required to use liner cap:
Re-attach the existing top of the chimney cap.  
Option two - Using liner cap: 
Re-attach the existing top of the chimney cap and install a 
new storm collar and a new liner cap.  
*You will need to add additional clearances to these
dimensions for your specific installation. Also allow suf-
ficient clearance if you are installing an outside air kit.