SJ300 Inverter
Oper
ati
ons
and Monitor
ing
4–73
Parameters for the second motor and third motors have function codes of the form x2xx and 
x3xx respectively. They appear immediately after the first motor’s parameter in the menu 
listing order. The following table lists the parameters that have the second/third parameter 
registers for programming.
Function Name
Parameter Codes
1st motor
2nd motor
3rd motor
Multi-speed frequency setting
A020
A220
A320
Acceleration time setting (Acceleration 1)
F002
F202
F302
Deceleration time setting (Deceleration 1)
F003
F203
F303
Second acceleration time setting (Accelera-
tion 2)
A092
A292
A392
Second deceleration time setting (Decelera-
tion 2)
A093
A293
A393
Select method to use 2nd acceleration/deceler-
ation
A094
A294
Acc1 to Acc2 frequency transition point
A095
A295
Dec1 to Dec2 frequency transition point
A096
A296
Level of electronic thermal setting
B012
B212
B312
Select electronic thermal characteristic
B013
B213
B313
Torque boost method selection
A041
A241
Manual torque boost value
A042
A242
Manual torque boost frequency adjustment
A043
A243
A343
V/F characteristic curve selection
A044
A244
A344
Base frequency setting
A003
A203
A303
Maximum frequency setting
A004
A204
A304
Select motor constant
H002
H202
Motor capacity setting
H003
H203
Motor poles setting
H004
H204
Motor constant R1 setting (Standard, Auto 
tuning)
H020/H030
H220/H230
Motor constant R2 setting (Standard, Auto 
tuning)
H021/H031
H221/H231
Motor constant L setting (Standard, Auto 
tuning)
H022/H032
H222/H232
Motor constant Io setting (Standard, Auto 
tuning)
H023/H033
H223/H233
Motor constant J setting (Standard, Auto 
tuning)
H024/H034
H224/H234
Motor constant Kp setting (Standard, Auto 
tuning)
H005
H205
Motor stabilization constant
H006
H206