Справочник Пользователя для Mitsubishi Electronics FR-E720-0.1KSC to 15KSC

Скачать
Страница из 60
35
Parameter list
7.2 Parameter list
REMARKS
 
 indicates simple mode parameters. (initially set to extended mode)
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
Parameter
Name
Setting 
Range
Initial 
Value
 0
Torque boost
0 to 30%
6/4/3/2%
 
 1
Maximum frequency
0 to 120Hz
120Hz
 2
Minimum frequency
0 to 120Hz
0Hz
 3
Base frequency
0 to 400Hz
60Hz
 4
Multi-speed setting (high 
speed)
0 to 400Hz
60Hz
 5
Multi-speed setting (middle 
speed)
0 to 400Hz
30Hz
 6
Multi-speed setting (low 
speed)
0 to 400Hz
10Hz
 7
Acceleration time
0 to 3600/
360s
5/10/15s
 8
Deceleration time
0 to 3600/
360s
5/10/15s
 9
Electronic thermal O/L relay
0 to 500A
Rated 
inverter 
current
10
DC injection brake operation 
frequency
0 to 120Hz
3Hz
11
DC injection brake operation 
time
0 to 10s
0.5s
12
DC injection brake operation 
voltage
0 to 30%
6/4/2%

13
Starting frequency
0 to 60Hz
0.5Hz
14
Load pattern selection
0 to 3
0
15
Jog frequency
0 to 400Hz
5Hz
16
Jog acceleration/deceleration 
time
0 to 3600/
360s
0.5s
17
MRS input selection
0, 2, 4
0
18
High speed maximum 
frequency
120 to 400Hz
120Hz
19
Base frequency voltage
0 to 1000V, 
8888, 9999
9999
20
Acceleration/deceleration 
reference frequency
1 to 400Hz
60Hz
21
Acceleration/deceleration time 
increments
0, 1
0
22
Stall prevention operation level 0 to 200%
150%
23
Stall prevention operation level 
compensation factor at double 
speed
0 to 200%, 
9999
9999
24
Multi-speed setting (speed 4)
0 to 400Hz, 
9999
9999
25
Multi-speed setting (speed 5)
0 to 400Hz, 
9999
9999
26
Multi-speed setting (speed 6)
0 to 400Hz, 
9999
9999
27
Multi-speed setting (speed 7)
0 to 400Hz, 
9999
9999
29
Acceleration/deceleration 
pattern selection
0, 1, 2
0
30
Regenerative function 
selection
0, 1, 2
0
31
Frequency jump 1A
0 to 400Hz, 
9999
9999
32
Frequency jump 1B
0 to 400Hz, 
9999
9999
33
Frequency jump 2A
0 to 400Hz, 
9999
9999
34
Frequency jump 2B
0 to 400Hz, 
9999
9999
35
Frequency jump 3A
0 to 400Hz, 
9999
9999
36
Frequency jump 3B
0 to 400Hz, 
9999
9999
37
Speed display
0, 0.01 to 
9998
0
40
RUN key rotation direction 
selection
0, 1
0
41
Up-to-frequency sensitivity
0 to 100%
10%
42
Output frequency detection
0 to 400Hz
6Hz
43
Output frequency detection for 
reverse rotation
0 to 400Hz, 
9999
9999
44
Second acceleration/
deceleration time
0 to 3600/
360s
5/10/15s
45
Second deceleration time
0 to 3600/
360s, 9999
9999
46
Second torque boost
0 to 30%, 
9999
9999
47
Second V/F (base frequency) 0 to 400Hz, 
9999
9999
48
Second stall prevention 
operation current
0 to 200%, 
9999
9999
51
Second electronic thermal O/L 
relay
0 to 500A, 
9999
9999
52
DU/PU main display data 
selection
0, 5, 7 to 12, 
14, 20, 
23 to 25, 
52 to 57, 61, 
62, 100
0
54
FM terminal function selection
1 to 3, 5, 
7 to 12, 14, 
21, 24, 52, 
53, 61, 62
1
55
Frequency monitoring 
reference
0 to 400Hz
60Hz
56
Current monitoring reference
0 to 500A
Rated 
inverter 
current
57
Restart coasting time
0, 0.1 to 5s, 
9999
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function selection
0, 1, 2, 3
0
60
Energy saving control 
selection
0, 9
0
61
Reference current
0 to 500A, 
9999
9999
62
Reference value at 
acceleration
0 to 200%, 
9999
9999
63
Reference value at 
deceleration
0 to 200%, 
9999
9999
65
Retry selection
0 to 5
0
66
Stall prevention operation 
reduction starting frequency
0 to 400Hz
60Hz
67
Number of retries at fault 
occurrence
0 to 10, 
101 to 110
0
Parameter
Name
Setting 
Range
Initial 
Value