Справочник Пользователя для Mitsubishi Electronics FR-E720-0.1KSC to 15KSC

Скачать
Страница из 60
37
Parameter list
180
RL terminal function selection
0 to 5, 7, 8, 
10, 12, 
14 to 16, 18, 
24, 25, 
62, 65 to 67, 
9999
0
181
RM terminal function selection
1
182
RH terminal function selection
2
183
MRS terminal function 
selection
24
184
RES terminal function 
selection
62
190
RUN terminal function 
selection
0, 1, 3, 4, 7, 
8, 11 to 16, 
20, 25, 26, 
46, 47, 64, 
68
, 80, 81, 
90, 91, 93, 
95, 96, 98, 
99, 100, 101, 
103, 104, 
107, 108, 
111 to 116, 
120, 125, 
126, 146, 
147, 164, 
168

, 180, 
181, 190, 
191, 193, 
195, 196, 
198, 199, 
9999
0
191
FU terminal function selection
4
192
A,B,C terminal function 
selection
0, 1, 3, 4, 7, 
8, 11 to 16, 
20, 25, 26, 
46, 47, 64, 
68
, 80, 81, 
90, 91, 95, 
96, 98, 99, 
100, 101, 
103, 104, 
107, 108, 
111 to 116, 
120, 125, 
126, 146, 
147, 164, 
168

, 180, 
181, 190, 
191, 195, 
196, 198, 
199, 9999
99
232
Multi-speed setting (speed 8)
0 to 400Hz, 
9999
9999
233
Multi-speed setting (speed 9)
0 to 400Hz, 
9999
9999
234
Multi-speed setting (speed 10)
0 to 400Hz, 
9999
9999
235
Multi-speed setting (speed 11)
0 to 400Hz, 
9999
9999
236
Multi-speed setting (speed 12) 0 to 400Hz, 
9999
9999
237
Multi-speed setting (speed 13) 0 to 400Hz, 
9999
9999
238
Multi-speed setting (speed 14)
0 to 400Hz, 
9999
9999
239
Multi-speed setting (speed 15)
0 to 400Hz, 
9999
9999
240
Soft-PWM operation selection 0, 1
1
241
Analog input display unit 
switchover
0, 1
0
244
Cooling fan operation 
selection
0, 1
1
245
Rated slip
0 to 50%, 
9999
9999
246
Slip compensation time 
constant
0.01 to 10s
0.5s
Parameter
Name
Setting 
Range
Initial 
Value
247
Constant-power range slip 
compensation selection
0, 9999
9999
249
Earth (ground) fault detection 
at start
0, 1
0
250
Stop selection
0 to 100s, 
1000 to 1100s, 
8888, 9999
9999
251
Output phase loss protection 
selection
0, 1
1
255
Life alarm status display
(0 to 15)
0
256
Inrush current limit circuit life 
display
(0 to 100%)
100%
257
Control circuit capacitor life 
display
(0 to 100%)
100%
258
Main circuit capacitor life 
display
(0 to 100%)
100%
259
Main circuit capacitor life 
measuring
0, 1 
(2, 3, 8, 9)
0
261
Power failure stop selection
0, 1, 2
0
267
Terminal 4 input selection
0, 1, 2
0
268
Monitor decimal digits 
selection
0, 1, 9999
9999
269
Parameter for manufacturer setting. Do not set.
270
Stop-on contact control 
selection
0, 1
0
275
Stop-on contact excitation 
current low-speed multiplying 
factor
0 to 300%, 
9999
9999
276
PWM carrier frequency at 
stop-on contact
0 to 9, 9999
9999
277
Stall prevention operation 
current switchover
0, 1
0
278
Brake opening frequency
0 to 30Hz
3Hz
279
Brake opening current
0 to 200%
130%
280
Brake opening current 
detection time
0 to 2s
0.3s
281
Brake operation time at start
0 to 5s
0.3s
282
Brake operation frequency
0 to 30Hz
6Hz
283
Brake operation time at stop
0 to 5s
0.3s
286
Droop gain
0 to 100%
0%
287
Droop filter time constant
0 to 1s
0.3s
292
Automatic acceleration/
deceleration
0, 1, 7, 8, 11
0
293
Acceleration/deceleration 
separate selection
0 to 2
0
295
Magnitude of frequency 
change setting
0, 0.01, 0.1, 
1, 10
0
296
Password lock level
0 to 6, 99, 
100 to 106, 
199, 9999
9999
297
Password lock/unlock
(0 to 5), 
1000 to 9998, 
9999
9999
298
Frequency search gain
0 to 32767, 
9999
9999
299
Rotation direction detection 
selection at restarting
0, 1, 9999
0
338
Communication operation 
command source
0, 1
0
339
Communication speed 
command source
0, 1, 2
0
340
Communication startup mode 
selection
0, 1, 10
0
342
Communication EEPROM 
write selection
0, 1
0
343
Communication error count
0
Parameter
Name
Setting 
Range
Initial 
Value