1.2.3
Changing the parameter setting value
Changing 
example
Change the Pr. 1 Maximum frequency setting.
Operation Display 
1.
Screen at power-ON
The monitor display appears.
2.
Press 
 to choose the PU operation mode.
PU indicator is lit.
3.
Press 
 to choose the parameter setting 
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
4.
Turn  
until 
 
(Pr. 1) appears.
5.
Press 
 to read the currently set value.
"
"(120.0Hz (initial value)) appears.
6.
Turn 
 to change the set value to 
"
" (60.00Hz).
7.
Press 
 to set.
Flicker...Parameter setting complete!!
 Turn 
 to read another parameter.
 Press 
 to show the setting again.
 Press 
 twice to show the next parameter.
 Press 
 twice to return the monitor to frequency monitor.
REMARKS
 is displayed...Why?
 appears ....................Write disable error
 appears ....................Write error during operation
 appears ....................Calibration error
 appears ....................Mode designation error
(For details, 
 Refer to the Instruction Manual (Applied).)
The number of digits displayed on the operation panel is four. Only the upper four digits of values can be displayed and set. If the
values to be displayed have five digits or more including decimal places, the fifth or later numerals can not be displayed nor set.
(Example) For Pr. 1
When 60Hz is set, 60.00 is displayed.
When 120Hz is set, 120.0 is displayed and second decimal place is not displayed nor set.
to