Parameter clear/all parameter clear
POINT
  Set "1" in Pr.CL Parameter clear, ALLC all parameter clear to initialize all parameters. (Parameters are not cleared
when "1" is set in Pr. 77 Parameter write selection.)
Refer to the extended parameter list of 
 the Instruction Manual (Applied) for parameters cleared with this
operation.
Operation Display 
1.
Screen at power-ON
The monitor display appears.
2.
Press 
to choose the PU operation mode.
PU indicator is lit.
3.
Press 
 to choose the parameter setting 
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
4.
Turn 
 until 
 (
) appears.
Parameter clear
All parameter clear
5.
Press 
 to read the currently set value.
"
"(initial value) appears.
6.
Turn 
 to change it to the set value "
".
7.
Press 
 to set.
Parameter clear
All parameter clear
Flicker ··· Parameter setting complete!!
 Turn 
 to read another parameter.
 Press 
 to show the setting again.
 Press 
 twice to show the next parameter.
Setting
Description
0
Not executed.
1
Sets parameters back to the initial values. (Parameter clear sets back all parameters except 
calibration parameters and terminal function selection parameters to the initial values.) Refer to the 
parameter list of 
 the Instruction Manual (Applied) for availability of parameter clear and all 
parameter clear.
REMARKS
 are displayed alternately ... Why?
 The inverter is not in the PU operation mode.
 PU connector or USB connector is used.
1. Press 
. [PU] is lit and the monitor (4-digit LED) displays "1". (When Pr. 79 = "0" (initial value))
2. Carry out operation from step 6 again.
and