5. Peripheral Devices 
 
 
 
 
 
5 - 5
5-2-2  Selection of contactor 
 
Select the contactor as in the expression below. 
 
Unit type 
MDS-R- 
V1-20 V1-40 V1-60 V1-80 
Recommended 
contactor 
(Mitsubishi Electric 
Corp.: option part)
 
S-N12 
-AC200V 
S-N18 
-AC200V
S-N20 
-AC200V
S-N25 
-AC200V
Free-air thermal 
current of the 
recommended 
contactor 
20A 25A 32A 50A 
 
Unit type 
MDS-R- 
V2-2020 V2-4020
V2-4040
V2-6040
V2-6060
V2-8040 V2-8060 V2-8080
Recommended 
contactor 
(Mitsubishi Electric 
Corp.: option part)
 
S-N18 
-AC200V 
S-N20 
-AC200V
S-N20 
-AC200V
S-N20 
-AC200V
S-N25 
-AC200V
S-N25 
-AC200V 
S-N25 
-AC200V 
S-N25 
-AC200V
Free-air thermal 
current of the 
recommended 
contactor 
25A 32A 32A 32A 50A 50A 50A 50A 
Option part: A breaker is not prepared as an NC unit accessory, so purchase the part from your dealer, etc. 
 
 
 
 
 
POINT
 
1.  Use an alternating contactor. 
2.  Select a contactor whose excitation coil does not operate at 15mA or less.