7. Wiring and Connection 
 
 
 
 
 
7 - 5
7-2-2  Main circuit and control circuit connector signal names and applications 
 
The following table shows the details for each terminal block signal. 
 
Name Signal 
name 
Description 
L1 . L2 . L3 
Main circuit 
power supply 
Main circuit power supply input terminal 
Connect a 3-phase 200 to 230VAC, 50/60Hz power supply. 
P, C 
Regenerative 
resistor 
Regenerative resistor connection terminal 
Connect the regenerative resistor. 
U . V . W 
Motor output 
Servomotor power output terminal 
The servo/spindle motor power terminal (U, V, W) is connected. 
PE 
Protective 
grounding 
(PE) 
Grounding terminal 
The servomotor/spindle motor grounding terminal is connected and 
grounded. 
VDD, SG 
Control circuit 
power supply 
Control circuit power supply input terminal 
Connect 24VDC.