OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
Major  physical  or  electrical
damage is evident.
1. Contact  your  local  Lincoln
Electric authorized field service
facility. 
1. Contact Lincoln Electric Service
Department 1-888-935-3877.
The  machine  is  dead--no  open
circuit  voltage  and  no  wire  feed
when  the  gun  trigger  is  activated.
The cooling fan is not running.
1. Make  certain  the  input  power
switch  (S1)  is  in  the  “ON”
position.
2. Check  the  input  voltage  at  the
machine.    The  input  voltage
must match the rating plate and
the reconnect panel.
3. Check  for  blown  or  missing
fuses in the input lines.
1. Check  the  input  power  switch
(S1).  It may be faulty.
2. Check  for  broken  or  missing
wires at the reconnect panel.
3. Perform the Main Transformer
There is no open circuit voltage or
wire  feed  when  the  gun  trigger  is
activated.    The  cooling  fan  is
running.
1. Make  sure  the  input  voltage  is
correct  and  matches  the
nameplate rating and reconnect
panel configuration.
2. One of the two thermostats may
be  open  due  to  machine
overheating.    If  the  machine
operates  normally  after  a
cooling off period then check for
proper  fan  operation  and
ventilation.    Make  certain  the
machine’s  duty  cycle  is  not
being exceeded.
1.  The  baffle  mounted  rectifier
bridge  may  be  faulty.    Check
and replace if necessary.
2. Perform the Main Transformer
3. Check  the  thermostats  and
associated  leads  for  loose  or
faulty  connections.    See  the
Wiring Diagram.
4. The 
internal 
triggering
circuit/plugs may be faulty.  See
the Wiring Diagram.
5. The control board may be faulty.
TROUBLESHOOTING AND REPAIR
F-4
F-4
Power MIG® 215XT