OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
Output voltage and wire feed speed
is  present  when  the  gun  trigger  is
NOT activated.
1.  Remove the gun assembly.  If the
problem  is  resolved,  the  gun
assembly  is  faulty.    Repair  or
replace.    If  the  problem  is  NOT
resolved,  the  fault  is  within  the
Power MIG® 215XT machine.
1.  Check for “shorts” in the trigger
circuitry within the Power MIG®
215XT  machine.    See  the
Wiring Diagram.
2.  The control board may be faulty.
The machines output is low.  Welds
are  “cold”.    The  weld  beads  are
rounded  or  “humped”  demonstrat-
ing poor wetting into the plate.  The
machine  cannot  obtain  full  rated
output of 200 amps at 22VDC.
1.  Check  the  input  voltage.    Make
sure  the  machine  is  configured
properly  for  the  input  voltage
being applied.
2.  Make  sure  the  settings  for  wire
feed  speed  and  voltage  are  cor-
rect for the process being used.
3.  Make  sure  the  electrode  polarity
is  correct  for  the  process  being
used.
4.  Check  the  welding  cables  and
gun  for  loose  or  faulty  connec-
tions.
1.  Check  for  loose  or  faulty  con-
nections  on  the  heavy  current
carrying leads inside the Power
MIG®  215XT.    See  the  Wiring
Diagram.
2.  The  output  capacitors  may  be
faulty.  Check for loose connec-
tions  at  the  capacitors.    Also
check  for  leaky  capacitors.
Replace if necessary.
WARNING:  The liquid electrolyte
in  these  capacitors  is  toxic.
Avoid contact with any portion of
your body.
3.  The  output  selector  switch  may
be  faulty.    Check  for  good  con-
tact  and  continuity  (zero  ohms)
through  the  switch.    See  the
Wiring Diagram.
4.  Perform  the  Output  Contactor
5.  Perform  the  Output  Bridge
6.  Perform the Main Transformer
The  output  voltage  is  continuous
when  the  gun  trigger  is  NOT  acti-
vated.  The wire feed functions nor-
mally.
1.  The  output  contactor  may  be
stuck closed.
1.  Perform  the  Output  Contactor
TROUBLESHOOTING AND REPAIR
F-6
F-6
Power MIG® 215XT