FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
There is no gas flow when the gun
trigger is activated .  The wire feeds
and the arc voltage is present.
1. If a spool gun adapter is installed,
make certain the toggle switch in
the  spool  gun  kit  in  the  correct
position.
2. Check to make sure the switch on
the  Magnum  100SG  Adapter
Panel  is  in  the  Magnum  Push
Gun Position.
3. Check the gas source and hoses
for kinks or leaks.
1. Check plug J1 on the control board
for loose or faulty connections.  See
Wiring Diagram.
2. Check  the  gas  solenoid  by  discon-
necting  it  from  leads  #108A  and
#116A&B.  Apply a 12VDC external
supply  to  the  solenoid.    If  the  sole-
noid does NOT activate then it may
be faulty.  Replace. 
The  machine  stops  feeding  wire
while  welding.    When  the  gun  trig-
ger  is  released  and  pulled  again,
the wire feed starts.
1. Check for a mechanical restriction
in  the  wire  feed  path.    The  gun
may be clogged.
2. Make  sure  the  drive  rolls  and
guide plates are clean and are the
correct size.
3. Check the spindle for ease of rota-
tion.
1. Check  the  motor  armature  current.
Normal armature current is 2.0 to 2.7
amps maximum.  If the motor arma-
ture current is normal, and the motor
continues  to  shut-off,  the  control
board may be faulty.  Replace.
2. If the motor armature current is high
(over  2.7  amps)  and  there  are  NO
restrictions  in  the  wire  feeding  path
then  the  motor  or  gearbox  may  be
defective.  Replace.
TROUBLESHOOTING AND REPAIR
F-7
F-7
Power MIG® 215XT