3.  Tool Offset (L system) 
3.1  Wear Data 
 
 
 
I-80 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.1.3  Tool Wear and Tool Length Data Setting Mode (incremental/absolute) 
 
There are two types of selection method in the absolute value setting or incremental value setting for the 
tool offset data: the mode selection method and the menu selection method. 
The required method is selected with the parameter #1136 optype. 
 
 
Absolute 
setting 
(Old) 
Incremental setting 
(New)
 
 
 
 (Example) 
 Incremental/absolute value setting 
 
          Setting                                                Display 
 
  • Incremental value setting 
  #  (2)  (  -    0.1) 
      #2  X-100.100 
 
 
 • Absolute value setting 
  #  (2)  (  -  100.1) 
      #2  X-100.100 
              Display 
 
  #2  X    -100.000 
 
 
 
(1)  Mode selection method (#1136=0) 
 
(a)  Change over to the incremental value setting mode 
 
 
Set I in # (    ), then press the 
 
 
INPUT
 key. 
 
# (  I) X (   ) Z (   ) 
 [TOOL DATA] 
 #I:INC. 
  #A:ABS. 
 
 
"#1: INC." is highlighted, and the mode becomes the 
incremental value setting mode. 
 
 
 
(b)  Change over to the absolute value setting mode 
 
 
Set A in # (    ), then press the 
 
 
INPUT
 key. 
 
# (  A) X (   ) Z (   ) 
 [TOOL DATA] 
 #I:INC.  
 #A:ABS. 
   
 
 
"#A: ABS." is highlighted, and the mode becomes the 
absolute value setting mode. 
 
 
 
(Note)  The mode is held even if the screen is changed or the power is turned OFF.