3.  Tool Offset (L system) 
3.2  Tool Length Data 
 
 
 
I-89 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.2.2  Manual Numeric Command Operation on the TOOL DATA Screen (M, T) 
 
When carrying out a manual numeric command of the TOOL OFFSET screen, the mode must first be 
changed from the normal data setting mode to the manual numeric command mode. M and T commands 
can be executed by screen operation in this mode.  
 
 
(1)  Changing from the normal data setting mode to the 
manual numerical command mode 
A cursor appears in the data setting area in the normal 
data setting mode, but a cursor does not appear in the 
manual numerical command mode. Confirm that the 
mode has changed over by checking this difference. The 
operation is as follows: 
T                      M 
#(          )DATA (              ) 
 
 
 
Set 
 
 
  (manual) in the first set of 
parentheses in the setting area. 
T                      M 
#(      M )DATA (              ) 
 
1)  This operation is the same for M or T 
commands. 
 
 
Press the 
 
 
INPUT 
  key. The mode 
changes to the manual numerical 
command mode. 
T                      M 
#(          )DATA (              ) 
 
1)  The data in the setting area is cleared, and 
the cursor disappears from the screen.  
 
(2)  Executing the manual numeric command ..... Carry out this step after (1) above. 
 
1.  Press the address key corresponding to the command. The display area of the corresponding 
command value is highlighted, and a manual numeric command input status results. Execute tool 
function commands with 
 
 
, and miscellaneous function commands with 
 
 
.  
 
2.  Key-input the numerical value to be commanded.  
 3. 
Press 
the 
 
 
INPUT 
 key. The command is executed.  
(Note)  The manual numeric command operation is the same as the operation on the POSITION screen. 
Refer to the section on manual numeric commands for the MONITOR and POSITION screens for 
details. 
 
(3)  Operation for returning the mode from the manual numeric command mode to the normal data setting 
mode 
 
Press the 
 
 
 
  key. The normal data 
setting mode returns. 
T20                      M6 
#(          )DATA (              ) 
 
 
1)  The cursor appears in the first set of 
parentheses, and the normal setting mode is 