3.  Tool Offset (L system) 
3.6  Tool Registration 
 
 
 
I-109 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.6.4  Deleting Tool Registration Data 
 
Press the 
 
 
INPUT 
 key. 
All data displayed in USAGE and 
MG1 to MGn is cleared to 0. 
Set CL in MG (      ). 
 
 
(Note) If any other key has been pressed before the 
 
 
INPUT
 key is pressed, the tool registration data will 
not be deleted. 
 
 
3.6.5  Manual Numeric Command Operation (M, T) on the TOOL REGISTRATION Screen 
 
To carry out manual numeric commands on the TOOL REGISTRATION screen, the mode must first be 
changed from the normal data setting mode to the manual numeric command mode. M and T commands 
can be executed by screen operation in the manual numeric command mode.  
 
(1)  Changing from the normal data setting mode to the 
manual numeric command mode 
A cursor appears in the data setting area in the normal 
data setting mode, but a cursor does not appear in the 
manual numeric command 
mode. 
Confirm that the mode has changed over by 
checking this difference. The operation is as follows: 
 
Set 
 
 
  (manual) in the first set of 
parentheses in the setting area. 
T                M 
MG(  M ) TOOL(         )  D( ) AUX( ) 
 
 
1) This operation is the same for M or T 
commands.  
 
 
Press the 
 
 
INPUT 
  key. The mode 
changes to the manual numerical 
command mode.   
T                M 
MG(    ) TOOL(         )  D( ) AUX( ) 
 
 
1) The data in the setting area is cleared, and the 
cursor disappears from the screen.  
 
T                M 
MG(    ) TOOL(         )  D( ) AUX( )