Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
3.  Tool Offset (M system) 
3.1  Tool Offset 
 
 
 
I-114 
Refer to "3 (I). Tool Offset (L system)" for L system.
Example of setting tool offset data in absolute mode 
 
Radius comp. 
Absolute value   3.0 
setting 
Length 
comp. 
40.0
Old New
Radius comp.
5.0
Length comp.   
Absolute value setting
37.0 
 
 
 
Display 
#3 40.000 
        Setting                                          Display 
  #    (    3)    (      37)                          #3    37.000
(#3 length compensation data) 
 
 
 
 
(b) Incremental value setting 
 
 
 
Change to the incremental value setting mode as follows: 
 
 
 
 [TOOL OFFSET] 
 #A:ABS.  
 #I:INC. 
 
Enter I in # (        ), then press the 
 
 
INPUT
key. 
        #    (      I) DATA(          )   
 
"#I: INC." is displayed in reverse video indicating 
that the incremental value setting mode is valid. 
 
Example of setting tool offset data in incremental value setting mode 
 
Radius comp. 
Incremental      -2.0
value setting 
 
Length 
comp. 
40.0
Old New
Radius comp.
5.0
 
Length comp.   
Incremental 
value setting 
-3.0 
 
 
 
Display 
#3 40.000 
        Setting                                          Display 
  #    (    3)    (      -3)                          #3    37.000
(#3 length compensation data)
 
 
 
 
The mode thus set is retained even after the screen is changed or after power has been turned OFF.