4.  Parameters (User) 
4.2  Machining Parameters 
 
 
 
I-146 
4.2  Machining Parameters 
 
 
Pressing the menu key 
 
 
PROCESS 
 displays the PROCESS PARAMERTER screen. 
 
The number of digits in the decimal section of the parameters related to length is determined by the input 
setting unit. 
 
The input setting unit is set with parameter "#1003 iunit". 
Input setting unit  No. of digits in decimal section
Example of setting range 
0 to 999.999 (mm) 
0 to 99.9999 (mm) 
0 to 9.99999 (mm) 
 
The setting ranges indicated in this manual use the input setting unit "B". 
 
 
4.2.1  PROCESS PARAMERTER 
 
 
 [PROCESS PARAMETER] 
PARAM  1.1/8 
 
  #   -  <WRK COUNT> 
#   - <AUTO CORNER OVR.> 
#   - <FIXED C.> 
  8001 
WRK COUNT M  0 
8007  OVERRIDE 
8012  G73 n 
0.000 
  8002 
WRK COUNT 
8008  MAX ANGLE 
8013  G83 n 
0.000 
  8003 
WRK LIMIT 
8009  DSC.ZONE 
0.000 
8014  CDZ-VALE 
   
 
 
 
8015  CDZ-ANGLE 
   
 
 
 
8016  G71 MINIMUM  0.000 
  #   -  <AUTO TLM> 
#   - <T-TIP OFFSET> 
 
8017      DELTA-D 
0.000 
  8004 
SPEED 
 0 
8010  ABS.MAX. 
0.000 
8018  G84/G74n 
0.000 
  8005 
ZONE  r 
0.000 
8011  INC.MAX. 
0.000 
  8006 
ZONE  d 
0.000 
 
 
    #    (            )DATA (              )
 
 
WORK 
PROCESS 
I/O PAR 
SETUP 
MENU 
 
 
<WRK COUNT> (No. of workpieces machined) 
# Item 
Contents 
Setup 
range 
(unit)
8001  WRK COUNT M 
Set the M code that counts the No. of workpiece 
repeated machining. 
The No. will not be counted when set to 0. 
0 to 99 
8002  WRK COUNT 
The current machining No. is displayed. Set the 
initial value. 
0 to 999999 
8003  WRK LIMIT 
Set the maximum No. of workpieces machined. 
A signal is output to PLC when the No. of machining 
times is counted to this limit. 
0 to 999999 
 
<AUTO TLM> (Automatic tool length measurement)  
# Item 
Contents 
Setup 
range 
(unit)
8004  SPEED 
Set the feedrate during automatic tool length 
measurement. 
1 to 60000 (mm/min)
8005  ZONE r 
Set the distance between the measurement position 
and deceleration start point. 
0 to 99999.999 (mm)
8006  ZONE d 
Set the tolerable zone of the measurement position.
If the sensor signal turns ON in front of d before the 
measurement position‚ or if the signal does not turn 
ON after d is passed‚ an alarm will occur. 
0 to 99999.999 (mm)