6.  Data In/Out 
6.1  DATA INPUT 
 
 
 
I-224 
6.1  DATA INPUT 
 
 
Pressing the menu key 
 
 
INPUT 
 displays the DATA INPUT screen. 
 
The DATA INPUT screen allows the operator to input user-created machining programs (main program and 
subprogram), tool offsets, parameters, common variables and history data. 
 
 
 [DATA INPUT] 
IN/OUT 
 <LOCK> 
#10 
MODE 
 # 1 MAIN PROGRAM   
    
1:IN
  2:COMP 
 # 2 TOOL DATA 
OFF 
#11 PORT 
No.2
 # 3 PARAMETER 
OFF 
#12 DEVICE 
No.1
  # 5  COMMON VARI 
OFF 
 
(FDD:9600bps) 
 #30 MACRO PROGRAM 
#28 AUX-PARA 
 #60 
TRACE 
DATA 
  <INPUT DATA> 
 
#99 MAINTENANCE 
 
   
 
 <COMP. DATA> 
 
  #(      )    DATA(                    ) (                )   
INPUT 
OUTPUT ERASE 
FILE 
MENU 
$1 
(Note 3) 
 
 
  # 
 Item 
 Explanation 
 1  MAIN 
PROGRAM 
(Note 1)  The types of data that can be input are indicated. 
(1)  Used when inputting the machining program. 
  2 
TOOL DATA 
(2)  Used when inputting the tool data. 
  3 
PARAMETER 
(3)  Used when inputting the parameter data. 
  5 
COMMON VARI 
(4)  Used to input a common variable. 
  28  AUX-PARA 
(5)  Used to input an auxiliary axis parameter data. 
  30  MACRO PROGRAM 
(6)  Used to input a macro program. 
  60  TRACE DATA 
(7)  Used to input history data. 
 10  MODE 
  1: IN 
  2: COMP 
The operation mode on the DATA INPUT screen is changed 
between IN (input) and COMP (comparison). After power is 
turned ON, IN mode is initiated. Since indication in active mode is 
highlighted, make sure that correct mode is selected before input 
or comparison operation. 
  11  PORT NO. 
The I/O port number and device number required to input data 
are set. 
  12  DEVICE NO. 
If they are already set on the I/O BASE PARAM screen, the setup 
values are displayed. They may be changed on either screen. 
 
 (Note 
1)  To input a fixed cycle program, set the parameter. 
 
 
 
  Refer to the Appendix 4 "Registration/Editing of Fixed Cycle Program". 
 
(Note 2)  The screen cannot be changed during data input. 
 (Note 
3)  When using the 2-part system, the system name of the currently selected system is displayed as 
$1 (system 1) and $2 (system 2). This is not displayed when using a 1-part system. (Only L 
system) 
 (Note 
4)  Whether to show or hide name of the selected system can be switched with the parameters. 
#1050 
MemPrg 
#1286 
ext22/bit0 
Details 
0, 2, 4, 6 
The name of the selected system is not displayed. 
1, 3, 5, 7 
OFF 
The name of the selected system is displayed. 
 
ON 
The name of the selected system is not displayed.