Справочник Пользователя для Mitsubishi Electronics 60/60S
6. Data In/Out
6.2 DATA OUTPUT
I-243
(3)
Data
format
The data format is as follows:
Address
Definition
Details
N
Parameter number
The parameter # number is shown with the value following N.
A
Axis number
For axis data, the axis number is shown with the value following A.
The first axis will be AI.
The first axis will be AI.
T
Axis system number For data per system, the system number is shown with the value
following T.
(1st system: T1, 2nd system: T2, PLC axis: T3)
(1st system: T1, 2nd system: T2, PLC axis: T3)
P
Parameter data
The parameter data is shown with the value following P.
The following types of data format are used according to parameter type and display method.
(The address order in one block must use the following format.)
1) Common parameter (one data item per one # number)
N 1 0 8 4 P 0 . 0 0 1 ;
Parameter setting value
Parameter # number
(1) The output parameter setting value is the same format as the screen display.
2)
Axis
parameter
N 2 0 0 1 A 1 P 1 0 0 0 0 ;
Parameter setting value
Axis number 1 to 4
# number on screen
(1) When multiple axes are displayed on one screen
The parameter data for when the parameters for multiple axes are displayed on one screen are
output per axis.
output per axis.
[Output
example]
:
N2001A1P120000 ;
N2002A1P4000 ;
N2003A1P21 ;
:
N2001A2P12000 ;
N2002A2P4000 ;
N2003A2P21 ;
:
Axis 2 data
Axis 1 data