1.  Setting and Display Unit Operation 
1.5  Data Setting Method 
 
 
 
I-13
 
1.5  Data Setting Method
 
 
 
(1)  Outline of data setting 
 
 
The data setting method consists 
mainly of the following steps: 
(1)  Enter the data number. 
(2)  Move the cursor. 
(3) Press data keys. 
(4)  Press the INPUT key. 
 
 
When a screen is selected, the cursor 
is displayed in the right end within the 
first parentheses in the setting area. 
 
 
RESERCH
PLC-SW
COM-VAR 
LOC-VAR MENU 
 [COMMON VARIABLE] 
MONITOR 7.1/11
 
 # 
 
 
110 
 100 
-123456.7890 
111 
 101 
     12.3456 
112 
 102 
 
 
113 
 103 
 
 
114 
 104 
 
 
115 
 105 
 
 
116 
 106 
 
 
117 
 107 
 
 
118 
 108 
 
 
119 
 109 
 
  #(            )DATA(                                    )NAME(              ) 
Data setting 
area 
Cursor
 
(1)  Enter the data number. 
 
Enter the number of the data to be set by 
using the numeric keys. 
(Example) To set data in #104, press 
                   
 
 
 
 
 
 
 
 
 
 
 
RESERCH
PLC-SW
COM-VAR 
LOC-VAR MENU 
  #( 104 )DATA(                                    )NAME(              ) 
 
(2)  Move the cursor. 
 
To move the cursor to the next 
parentheses, press the 
 
 
 
 key. 
 
 
 
RESERCH
PLC-SW
COM-VAR 
LOC-VAR MENU 
  #( 104 )DATA(                                    )NAME(              ) 
 (3) 
Press 
data 
keys. 
 
Seeing the data display area contents, 
enter new data by using the keys. 
(Example) To change to 12.345, press 
                     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RESERCH
PLC-SW
COM-VAR 
LOC-VAR MENU 
  #( 104 )DATA(                    12.345 )NAME(              ) 
 
(4)  Press the INPUT key. 
 
Check the setup contents displayed in the 
setting area and set the data in memory by 
pressing the 
 
 
INPUT 
 key. 
 
 
 
1)  Data setting processing is performed 
according to the setting area contents, 
and the result is displayed in the data 
display area. 
 
 
2)  The data number in the setting area is 
incremented by one, and the cursor is 
displayed in the right end within the 
second parentheses. 
 
 
 
After the last data number is input, it is 
not displayed. At this time, the cursor is 
displayed in the right end of the first 
parentheses. 
 
 
RESERCH
PLC-SW
COM-VAR 
LOC-VAR MENU 
 [COMMON VARIABLE] 
MONITOR 7.1/11
 
 # 
 
 
110 
 100 
-123456.7890 
111 
 101 
     12.3456 
112 
 102 
 
 
113 
 103 
 
 
114 
 104 
 
 
115 
 105 
 
 
116 
 106 
 
 
117 
 107 
 
 
118 
 108 
 
 
119 
 109 
 
 #(   105)DATA(                  )NAME(       )