2.  Monitor 
2.1  POSITION 
 
 
 
I-26
 
 (Note 
1)  If the type is BCD output and a negative number is set, the positive value converted from it will be 
output. 
  
 
(Example)  Manual numeric command 
 
Output
M  -100 
M  100
 
 
 (Note 
2)  If the number of digits specified in the command exceeds the setting range, the most significant 
digit will be lost. 
  
 
(Example) 
 
 
M   1234 
 
 
M   2345
Most significant digit is lost. 
1
 
 
 
 
 
(5)  Other notes on operation 
 
 
(1) When a minus command is set: 
 
 
 
Before setting the numeric, press the 
 
 
 
 key. 
  
 
(Example)  If S-150 is specified: 
 
 
Press address key 
 
 
. Then, press 
key 
 
 
 
 
 
 
 
 
 
 
 
 
 in order. 
Press the 
 
 
INPUT 
 key. 
 
 
 S-150   
 
 
 
 S 150      
1)  A minus value will be output, but a 
positive value will display. 
 
 
 
(2) When manual numeric command operation stops halfway: 
 
 
 
If the operation is desired to be stopped before input after pressing the address key, press any 
non-numeric key. 
 
 
 
•  If a manual numeric command address-key such as M, S, T is pressed, the previous operation 
will stop. In this case, the next manual numeric command sequentially begins. 
 
 
 
•  If an axis address key (X, Y, or Z, etc.) is pressed, the manual numeric command will stop. In this 
case, the origin zero or counter zero mode is then entered. 
  
 
• 
If 
the 
 
 
SHIFT 
 
   
C.B 
CAN 
 keys are pressed, the manual numeric command will stop. In this case, the 
POSITION screen is blanked. 
 
 
 
•  If one of the following keys is pressed, the operation will not stop: 
 
 
 
  1)  Position display function key 
 
MONI-
TOR 
 
 
 
 
  2)  
 
 
 
 key pressed before a numeric is set (will be processed as a minus command.) 
 
 
 
  3)  
   
DELETE 
INS 
 key when a numeric has been set (The set data will be deleted.) 
 
 
(3) The macro interruption codes (M96, M97) and subprogram call codes (M98, M99) will not be 
processed even if these codes are issued. 
 
 
(4) No surface speed command is available. 
 
 
 
In the constant surface speed mode, no command is processed, if specified.