8.  Maintenance Functions 
8.1  Data Input/Output Function 
 
 
 
III-67
 
 
(3)  Example of data input operation 
Confirm that the user PLC is 
stopped. 
 
Connect the input device.
 
 
Call out the data input screen. 
 
 
 
         
 
DIAGN 
IN/OUT
 
 
 
 
        
 
 
IN/OUT 
 
 
 
        
 
 
INPUT 
 
 
 
 
1)  The data input screen will display. 
 
2)  The input mode is valid when the 
screen is selected. 
 
 
Set 99 in # setting area. 
 
# (99) DATA (         ) 
<INPUT DATA> 
 N2L0L0L10001L10000; 
<COMP. DATA> 
 
 DATA 
IN 
EXECUTION 
  # (9 9 ) DATA (                          101 ) 
<INPUT DATA> 
 % 
<COMP. DATA> 
 
 DATA 
IN 
COMPLETE 
# (          ) DATA (                            )
1)  The input will start, and the input 
data details and "DATA IN   
EXECUTION" message will 
display. 
 
The No. of the data being input 
will display in the data setting 
area. 
2)  The input operation is com- 
pleted when the end code % 
(EOR) is read in. Then the 
parameters will be written into 
the EEROM. Do not turn off the 
power while the message 
"EEROM WRITE IN PROCESS" 
is displayed. 
 
When writing to the EEROM is 
completed, the message "DATA 
IN COMPLETE" will display. 
Press 
 
 
INPUT 
 key. 
<INPUT DATA> 
 
<COMP. DATA> 
 
 
# (9 9 ) DATA (                                  )