Справочник Пользователя для Mitsubishi Electronics 60/60S
2. Monitor
2.3 COMMAND
I-46
Display item
Explanation
The rotation angle for the program coordinate rotation command is
displayed.
displayed.
The scaling magnification is displayed.
G68: R=
(M system)
G51: P=
(M system)
G05: P10000 (M system)
The high-speed machining mode and high-speed high-accuracy
mode are displayed.
mode are displayed.
High-speed machining mode 3
(G05 : P3)
High-speed high-accuracy control II (G05 : P10000)
SSS control valid
SSS control valid
(G05 : P10000S)
High-speed high-accuracy control I (G05.1 : Q1)
Spline interpolation
Spline interpolation
(G05.1 : Q2)
Mode OFF
(G05 : P0)
Tx: –12.345
(L system)
Tz: 12.345 (L
system)
Tc: 10.000 (L
system)
The total of the X axis, Z axis and additional axis' tool length and
wear compensation amounts for the tool being used is displayed.
wear compensation amounts for the tool being used is displayed.
Tg: 12
(L
system)
Tw: 12
(L
system)
The tool length offset No. is displayed.
The wear compensation No. is displayed.
The wear compensation No. is displayed.
v
(L
system)
FA 24000.00
FM 1200.00
FS 0.0000
FE
FM 1200.00
FS 0.0000
FE
0.0000 (L system)
S 12345
T 1234
M 12345678 10 35 40
B 1234
The constant surface speed spindle rotation speed is displayed.
The program command asynchronous feedrate modal value
currently being executed is displayed. (mm/min)
The manual feedrate is displayed. (mm/min)
The program command synchronous feedrate modal value
currently being executed is displayed. (mm/rev)
The thread lead command synchronous feedrate modal value
currently being executed is displayed. (mm/rev)
The modal value of the current program command S being
executed is displayed.
The modal value of the current program command T being
executed is displayed.
A maximum of four modal values of the current program command
M being executed are displayed.
The second miscellaneous function modal value of the current
program command being executed is displayed.
The program command asynchronous feedrate modal value
currently being executed is displayed. (mm/min)
The manual feedrate is displayed. (mm/min)
The program command synchronous feedrate modal value
currently being executed is displayed. (mm/rev)
The thread lead command synchronous feedrate modal value
currently being executed is displayed. (mm/rev)
The modal value of the current program command S being
executed is displayed.
The modal value of the current program command T being
executed is displayed.
A maximum of four modal values of the current program command
M being executed are displayed.
The second miscellaneous function modal value of the current
program command being executed is displayed.
N300 G1X-100.234~
The current program block being executed is displayed.