Справочник Пользователя для Mitsubishi Electronics SDP-ECO 1630 III

Скачать
Страница из 83
Chapter 4   Operation
If the output data is sent from the host computer to the recorder while 
the above warning is being issued, the warning disappears, executing 
output operation. After output operation has been completed, the 
warning message appears and the buzzer sounds again.
Handling waste liquid
Scale lines indicating capacity are marked on the waste chemical tank.
Observe the scale line carefully and dispose of the processing chemical before
it reaches the 10-liter line.
When the waste chemical tank is full, the "Waste tank check" message appears
and a buzzer sounds. (Images cannot be read at this time.)
Dispose of the processing chemical following the procedure below.
1) Press the 
key to turn off the buzzer.
2) Remove the cap from the waste chemical tank and dispose of the waste
chemical in the tank.
3) Put the cap back on the now empty tank and put it back in the waste
chemical vat.
- The waste chemical tank weighs approximately 11 kilograms when it
is full, so please be very careful when handling it. (Refer to "1.3
Handling processing chemicals".)
- Be careful when handling the hose attached to the waste chemical
cap.  Using a crimped or twisted hose can cause chemical leakage.
If the machine is not used for a long period
Before deactivating the machine for a long time (7 days or more),
always drain the water in the rinse water replenisher bottle.
If the machine has not been used for a long time, the processor rack roller may
stick and not rotate smoothly.
Follow the procedure below so that the processor rack roller will rotate
smoothly.
1) Open the front door.
2) Remove the replenisher bottle
from the tank.
3) Hold the handle in the processor
rack section and slightly pull out
the processor rack.
- 33 -
Caution
Handle
Processor rack
Caution