SPECIAL PROCEDURES 
April 2007 
4-24 
To adjust the main machine: 
1.  Place the test charge Connection Kit Color Test Chart (P/N VSST9501) on the 
exposure glass, with the arrow mark on the chart aligned with the left rear 
corner. 
2. Do 
SP4954 001 (Read/Restore Std) and press [Execute]. 
After about 10 seconds, the "Completed" message appears. 
Important: If "Completed" appears immediately after pressing [Execute], the 
adjustment may have failed. Do the procedure again. 
3. After 
doing 
SP4954 001, do the ACC procedure. For more, see Section "1. 
Installation (Pg.1-33)" 
 
To adjust the sub machine: 
4.  Do Steps 1 to 3 for the sub machine. 
 
Compare the results 
5.  Set the two machines for full color, and do some sample color copies.  
6.  Compare the results from the two copiers. If the results are not good, do the 
procedure again from step 1.