5 - 8
MC9090-G RFID Integrator Guide Supplement
Settings
The Settings window is used to set the number of iterations to read tags. To set the class type(s) to read (Gen2 is
on by default). The settings window is also used to set and test read/write power. Tap File - Settings to display the
Settings window.
on by default). The settings window is also used to set and test read/write power. Tap File - Settings to display the
Settings window.
Figure 5-5
RFID - Settings Window
To establish settings:
•
Enter a number in the Read Tag Outer Loop: text box to set the number of outer inventory loops (iterations to
read tags). Up to 255 loops are allowed. The default Read Tag Outer Loop setting is 5.
read tags). Up to 255 loops are allowed. The default Read Tag Outer Loop setting is 5.
•
Enter a number in the Read Tag Inner Loop / Dwell text box to set the number of inner inventory loops
(iterations to read tags). Up to 255 loops are allowed. The default Read Tag Inner Loop setting is 3.
(iterations to read tags). Up to 255 loops are allowed. The default Read Tag Inner Loop setting is 3.
•
Select the Enable Gen2 Tag Reads (default setting is to read Gen2 tags) check box to enable the mobile
computer to read Gen2 tags.
computer to read Gen2 tags.
•
In the Attenuation area:
•
Set the read strength by moving the Read attenuation slide bar to a value in a range between 0 (full read
power) and 255 (low read power/off).
power) and 255 (low read power/off).
•
Set the write strength by moving the Write attenuation slide bar to a value in a range between 0 (full write
power) and 255 (low write power/off).
power) and 255 (low write power/off).
•
Tap OK to exit Settings.
•
Tap Read Toggle to test the attenuation settings. When tapped, Read Toggle acts like the mobile
computer’s trigger and can be used to test tag read and write strength.
computer’s trigger and can be used to test tag read and write strength.
Attenuation
slide bars
slide bars
Attenuation
values
NOTE
Read Tag Outer Loop and Read Tag Inner Loop settings attempt to read a tag for a period of
time based on the parameters entered in these fields. For more information, refer to the SMDK
Help file
time based on the parameters entered in these fields. For more information, refer to the SMDK
Help file
.