Settings
The Settings window is used to set the number of iterations to read tags. To set the class type(s) to read (Gen2 is 
on by default). The settings window is also used to set and test read/write power. Tap File - Settings to display the 
Settings window.
 Figure 5-5    
RFID - Settings Window
To establish settings:
Enter a number in the Read Tag Outer Loop: text box to set the number of outer inventory loops (iterations to 
read tags). Up to 255 loops are allowed. The default Read Tag Outer Loop setting is 5.
Enter a number in the Read Tag Inner Loop / Dwell text box to set the number of inner inventory loops 
(iterations to read tags). Up to 255 loops are allowed. The default Read Tag Inner Loop setting is 3.
Select the Enable Gen2 Tag Reads (default setting is to read Gen2 tags) check box to enable the mobile 
computer to read Gen2 tags.
In the Attenuation area:
Set the read strength by moving the Read attenuation slide bar to a value in a range between 0 (full read 
power) and 255 (low read power/off).
Set the write strength by moving the Write attenuation slide bar to a value in a range between 0 (full write 
power) and 255 (low write power/off).
Tap OK to exit Settings.
Tap Read Toggle to test the attenuation settings. When tapped, Read Toggle acts like the mobile 
computer’s trigger and can be used to test tag read and write strength.
Attenuation 
slide bars
Attenuation
values
NOTE
Read Tag Outer Loop and Read Tag Inner Loop settings attempt to read a tag for a period of 
time based on the parameters entered in these fields. For more information, refer to the SMDK 
Help file
.