Installation
24
IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide
2.8
Drive Enclosure Device Addressing
Each enclosure has 16 drive bays. The SEL_ID of each drive is determined by the device slot 
(0-15) in which it is installed and the address range setting, which is set by means of the 
Enclosure ID switch on the Ops Panel (shown in 
) at the rear of the 
enclosure. The switch settings are shown in Table 2–2
Figure 2–9
 Installing an SCM I/O Module in Bay 4 
Table 2–2
 Ops Panel Switch Functions (Default settings for DCS9550 1S1 Storage Expansion Unit 
SCM usage at 1Gb/s)
Switch 
Number
Function
Recommended 
Setting
Definition
1 thru 6
Not Used
Off
7 & 8
Drive Loop 
Speed Select
Sw 7
Sw 8
DCS9550 Controllers
On
Off
Force 2Gb/s
9 & 10
Drive 
Addressing 
Mode Selection
Sw 9
Sw 10
DCS9550 Controllers
Off
On
Mode 1