Справочник Пользователя для HP (Hewlett-Packard) 1900ux

Скачать
Страница из 80
Navigation
38
Table 5:  Configuration options
Configuration Name
Description
Default
RECOVERY ON/OFF
Toggles between 
ON 
and 
OFF
. If the configuration is set 
to 
ON
, the jukebox attempts to recover from errors; if the 
configuration is set to 
OFF
, the jukebox immediately 
stops moving if an error condition occurs. The default 
configuration is 
RECOVERY ON
, and recovery should 
remain 
ON 
under normal conditions.
RECOVERY ON
RESTORE DEFAULTS
Sets all jukebox configurations to default settings.
NA
CLEAR ODOMETERS
Sets all jukebox odometers to zero.
Note:  
Used by service personnel only.
NA
DUAL PICKER 
ON/OFF
Toggles between 
ON
 and 
OFF
.   (The default setting is 
DUAL PICKER ON
, and dual picker mode should 
remain 
ON
 under normal conditions.)  If the 
configuration is set to 
ON
, the jukebox runs with dual 
picker (disk transport) addressing 
ON
; if the 
configuration is set to 
OFF
, the jukebox runs with dual 
picker (disk transport) addressing 
OFF
.
DUAL PICKER 
ON
STARWARS ON/OFF
Should be set to 
ON
 during normal operation. Toggles 
between 
ON
 and 
OFF.
 The 
ON
 configuration enables 
the vertical sensors; the 
OFF
 configuration disables the 
vertical sensors.
Note:  
Used by service personnel only.
STARWARS ON
NEW PASSWORD
Allows you to change the numerical password required 
to access the menu choices under the 
ADMIN*
 menu on 
the jukebox control panel. 
000-000-000
SCSI LOG ON/OFF
Should be set to 
OFF
 during normal operation. Toggles 
between 
ON
 and 
OFF
. Tracks internal SCSI states and 
saves the information to a log.
Note:  
Used by service personnel only.
SCSI LOG 
OFF
SECURE MS ON/OFF
Toggles between 
ON
 and 
OFF
. The 
ON
 configuration 
disables loading and ejecting disks. The 
OFF
 
configuration 
enables loading and ejecting disks.
SECURE MS 
OFF