Справочник Пользователя для Q-Logic 8200 SERIES

Скачать
Страница из 118
3 – Getting Started with SANbox SSP
 
Connecting to the SAN
3-10
 
SN0054628-00  A
Q
3.4.2
 
Connecting SANbox SSPs to the SAN
For high-availability configurations, you must make sure that each SANbox SSP:
Can access all storage ports.
Is connected to both SVM appliances through the back-side fabric.
To connect SANbox SSPs to the SAN:
1. Using a standard multi-mode (62.5/125um) optical cable, connect ports 1 and 
2 of both SANbox SSPs to the switch labeled FC Switch A in the configuration 
diagram, shown in 
.
The status LED for each SANbox SSP port transitions from off (no light) to 
green when the port is connected to the SAN and the Fibre Channel link 
becomes active; the port LEDs are shown in 
Figure 3-5. SANbox 8200/8202 SSP Port LED Transitions
2. Connect ports 3 and 4 of both SANbox SSP to the switch labeled FC Switch B 
in the configuration diagram.
3. Create two zones: one on FC Switch A named Zone front_A, and another 
zone on FC Switch B named Zone front_B. 
4. Add the SANbox SSP ports connected to FC Switch A to both Zone front_A 
and Zone back_A.
5. Add the SANbox SSP ports connected to FC Switch B to both Zone front_B 
and Zone back_B.
Port 1 LED. Link is up when LED 
is green (cable not shown).
Port 2 LED. Link is down.