Component identification  54 
System maintenance switch 
 
Position Function 
Default 
1* 
iLO 2 security override 
Off 
2 Configuration 
lock 
Off 
3 Reserved 
Off 
4 Reserved 
Off 
5* Password 
disabled 
Off 
6* Reset 
configuration 
Off 
7 Reserved 
Off 
8 Reserved 
Off 
  
*To access redundant ROM, set S1, S5, and S6 to ON. 
 
System maintenance switch procedures 
When you perform troubleshooting steps, this guide may instruct you to perform the following procedures: 
 
Clear the system configuration ("
). 
 
Access the redundant ROM ("
To complete these procedures, you must change physical settings on the system maintenance switch. 
 
Clearing the system configuration 
RBSU can be used to restore the factory default configuration. For more information, see "HP ROM-Based 
Setup Utility (on page 
)." If the system is unable to boot into RBSU, use the following steps to clear the 
system configuration: 
1. 
Power down the server blade (on page 
2. 
3. 
Remove the access panel ("
4. 
Change position 6 of the system maintenance switch to on. 
5. 
). 
6. 
Install the server blade in the enclosure and power up the server blade. 
7. 
Wait for the POST message that prompts you to change the switch setting: 
Maintenance switch detected in the "On" position. 
Power off the server and turn switch to the "Off" position. 
8. 
Repeat steps 1 through 3. 
9. 
Change position 6 of the system maintenance switch to off. 
10. 
Repeat steps 5 through 7. 
  
 
IMPORTANT:
  When the server blade boots after NVRAM is cleared, a delay of up to 2 
minutes is normal. During this delay, the system appears non-functional. Do not attempt any 
procedures during the delay.