3. SIGNALS AND WIRING
3.1.2 Internal speed control mode
1
9
12
RA1
RA2
8
4
3
5
6
7
EMG
SON
ST1
ST2
LSP
LSN
SG
13
ALM
ZSP
CN3
VIN
CN1
4
3
SD
6
MO1
LG
MO2
10k
10k
A
A
CN3
20
19
21
17
16
18
LZ
LZR
LA
LAR
LB
LBR
LG
OP
SD
14
15
11
10
SA
RD
RA5
RA4
13
SG
Plate
(Note 9)
Servo configuration 
software
Personal
computer
CN1
(Note 8)
(Note 6)
Trouble
Zero speed
(Note 2, 4)
Control common
Encoder Z-phase pulse
(open collector)
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
(Note 7)
Communication cable
2m(6.5ft) max.
(Note 7)
Monitor output
Max.   1mA 
Reading in
both directions
(Note 1)
Servo amplifier
(Note 8)
Speed reached
Ready
Plate
(Note 3, 5) Emergency stop
Servo-on
Forward rotation start
Reverse rotation start
(Note 5) Forward rotation stroke end
Reverse rotation stroke end
External
power
supply
24VDC
10m(32ft) max.
(Note 8)
(Note 8)
(Note 10)
Note: 1. To prevent an electric shock, always connect the protective earth (PE) terminal (terminal marked   ) of the servo amplifier to
the protective earth (PE) of the control box.
2. Connect the diode in the correct direction. If it is connected reversely, the servo amplifier will be faulty and will not output
signals, disabling the emergency stop and other protective circuits.
3. The emergency stop switch (normally closed contact) must be installed.
4. The sum of currents that flow in the external relays should be 80mA max. If it exceeds 80mA, supply interface power from
external.(Refer to Section 3.6.2)
5. When starting operation, always connect the emergency stop signal (EMG) and forward/ reverse rotation stroke end signal
(LSN/LSP) with SG. (Normally closed contacts)
6. Trouble (ALM) is connected with COM in normal alarm-free condition.
7. When connecting the personal computer together with monitor outputs 1, 2, use the branch cable (MR-E3CBL15-P). (Refer to
Section 13.1.3)
8. The pins with the same signal name are connected in the servo amplifier.
9. Use MRZJW3-SETUP 154E.
10. Connect the external 24VDC power supply if the output signals are not used.