Host Software
RFID Application Kit ATAK2270 User Manual
5-17
4871E–RFID–04/08
The structure of the ATA5577 user interface differs from the other transponder types. 
In the Setup window, four tabs – Transp. Settings, Write, Read and ISO 11784 – and the Downlink sec-
tion allow the configuration, reading, writing and programming and reading transponder according ISO 
11784/85 standard.
5.3.6.2
Downlink Settings
The Downlink section, above the tabs, indicates the current downlink mode from the reader to the tran-
sponder. Downlink modes are selectable as follows:   
„
Downlink Protocol
Fixed Bit Length, Long Leading Reference or Leading Zero Reference
 
(1-of-4 Coding is not supported by the software)
„
Fast Write Method 
Not released for Basic Mode selection
„
Password Mode    
see 
Note, downlink write commands must be sent with the protocol mode that is currently used by the tran-
sponder, otherwise the transponder will not understand the command.
5.3.6.3
Transponder Setting tab
The Transp. Setting tab is divided into two sections. The first, the Configuration Setup on the left side, is 
used to define bit set of block0. The second section AFE-Option Setup, on the right, is used to adjust the 
behavior of Analog Front-End AFE via bit set of block3/page1. The resulting bit strings are displayed at 
the bottom of each section in the Bitstring of Configuration Block text boxes.
Click the Default Configuration Set restores the default Configuration Setup settings. Click the Default 
AFE-Option Set, restores the AFE options. The Reset Transponder button is used to isse a a reset com-
mand to transponder within the field. 
5.3.6.3.1 Configuration Setup:
Selected parameters are sent to the transponder by clicking the Write Configuration Set button. Default 
parameters are indicated in bold.     
„
Bitrate:
– Basic Mode 
Rf/8, Rf/16, Rf/32, Rf/40, Rf/50, Rf/64, Rf/100 and Rf/128
– Extended Mode 
Rf / (2n + 2) for n = 0 to 63 (default Rf/32)
„
Coding: 
Manchester, Biphase, direct, PSK..., FSK,... 
„
ID-Code Length: 
Block0, Block1, Block 1 to 2, Block 1 to 3, ..., Block 1 to 7
„
Password:
Activates password mode (default = not activated
 
(see 
)
„
Lock Config. Block: 
Locks the configuration block0 of the transponder (default = not 
 
activated
 
Once locked, the configuration can never be changed. Use this feature
 
with care
„
Answer On Request: 
Activates anticollision mode (selecting this shows an additional button on 
 
the read tab for AOR wake-up,