Справочник Пользователя для IBM XSERIES 220

Скачать
Страница из 178
 62
Hardware Maintenance Manual: xSeries 220
 
 
Do the following to remove the support bracket assembly:
1.
Review the information in  “Before you begin” on page 58.
2.
Turn off the server and peripheral devices and disconnect all external cables and 
power cords.
3.
4.
If the server is a non-hot-swap model, continue with step 7..
5.
If the server is a hot-swap model, press down on the latches on either side of 
connector J42, and remove the voltage regulator module (VRM) from connector 
J42. (See “System board options connectors” on page 55  for connector location.)
Note:
Remember to reinstall this VRM after you reinstall the support bracket 
assembly.
6.
Disconnect the fan cable (connector J10) from the system board.  (See “System 
board internal cable connectors” on page 55 f
or connector locations.)
Note:
Remember to reconnect this cable after you reinstall the support bracket 
assembly.
7.
Carefully pull up on the end of the support bracket assembly that is closer to the 
rear of the server; then, rotate and lift the support bracket assembly out of the 
server.
8.