Справочник Пользователя для Intel SE7520JR2

Скачать
Страница из 225
Platform Management 
Intel® Server Board SE7520JR2 
 
 
Revision 1.0 
C78844-002 
122 
 
5.2.1 
Server Management I
2
C Buses 
The table below describes the server management I
2
C bus assignments and lists the devices 
that are connected to the indicated bus. The column labeled “I
2
C Bus ID” represents the 
physical I
2
C bus connected to the mBMC.  Only the Peripheral SMBus is available for use with 
the Write-Read I
2
C IPMI command. 
Table 46: Server Management I
2
C Bus ID Assignments 
 I
2
C Bus ID 
Bus Name 
Devices Connected 
Host SMBus 
SMBus, PCI slots, ICH5, mBMC, DIMM FRU 
2 Peripheral 
SMBus 
SMLink, ICH5, mBMC, SIO 3, LM93, control panel, PDB, 
Baseboard Temp Sensor, BMC FRU 
Private Bus 4 – PB4 
Network Interface Chipset 
 
5.2.2 
Power Control Interfaces 
The mBMC is placed between the power button and the chipset so it can implement the Secure 
Mode feature of disabling the power button, and add additional power control sources to the 
system. In addition to the mandatory chassis controls, such as power–down and power-up, the 
mBMC supports power cycle and pulse diagnostic interrupt.  
The mBMC Chassis Control command supports the following power behavior. 
• 
Power down  (0h – Chassis Control command):  This option asserts a 4s override to the 
chipset  
• 
Soft Shutdown (5h – Chassis Control command):  This option generates a 200ms pulse of 
the chipset power button 
5.2.3 
External Interface to the mBMC 
The following figure shows the data/control flow to and within the functional modules of the 
mBMC. External interfaces, namely the host system, Lan-On-Motherboard (LOM), and 
peripherals interact with the mBMC through the corresponding interface modules.  
Power supply control functions and control panel control functions are built into the mBMC. The 
mBMC communicates with the internal modules using its private SMBus. External devices and 
sensors interact with the mBMC using the peripheral SMBus. LOM communicates through the 
LOM SMBus.