Error Reporting and Handling 
Intel® Server Board SE7520JR2 
 
 
Revision 1.0 
C78844-002 
152 
does not alter the BSP and attempts to boot from the original BSP. Error messages are 
displayed on the console, and errors are logged in the event log of a processor failure. 
If the user replaces a processor that has been marked bad by the system, the system must be 
informed about this change by running BIOS Setup and selecting that processor to be retested. 
If a bad processor is removed from the system, the BMC automatically detects this condition 
and clears the status flag for that processor during the next boot.  
Three states are possible for each processor slot: 
• 
Processor installed (status only, indicates processor has passed BIOS POST). 
• 
Processor failed. The processor may have failed FRB2, FRB3, or BIST, and it has been 
disabled. 
• 
Processor not installed (status only, indicates the processor slot has no processor in it). 
Additional information on the FRB may be found in the Sahalee Baseboard Management 
Controller EPS. 
6.2  Memory Error Handling 
The chipset will detect and correct single-bit errors and will detect all double-bit memory errors. 
The chipset supports 4-bit single device data correction (SDDC) when in dual channel mode.  
Both single-bit and double-bit memory errors are reported to baseboard management by the 
BIOS, which handles SMI events generated by the MCH. 
Memory Error Handling can be enabled or disabled in system BIOS Setup. 
6.2.1 
Memory Error Handling in RAS Mode 
The MCH supports two memory RAS modes: Sparing and Mirroring. Enabling of Sparing or 
Mirroring feature are mutually-exclusive. Use system BIOS Setup to configure memory RAS 
mode.