8.2.7 Capacitive 
Loading 
The power supply shall be stable and meet all requirements with the following capacitive 
loading ranges. 
Table 120: Capacitve Loading Conditions 
Output 
MIN 
MAX 
Units 
+3.3V 
250 
6,800 
µF 
+5V 
400 
4,700 
µF 
+12V(1, 2, 3) 
500 each 
11,000 
µF 
-12V 
350 
µF 
+5VSB 
20 
350 
µF 
 
8.2.8 
Closed Loop Stability 
The power supply shall be unconditionally stable under all line/load/transient load conditions 
including capacitive load ranges. A minimum of: 45 degrees phase margin and -10dB-gain 
margin
 is required. Closed-loop stability must be ensured at the maximum and minimum loads 
as applicable. 
8.2.9 
Common Mode Noise 
The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency 
band of 10Hz to 30MHz. 
8.2.10 
Ripple / Noise 
The maximum allowed ripple/noise output of the power supply is defined in the following table.  
This is measured over a bandwidth of 0Hz to 20MHz at the power supply output connectors.   
Table 121: Ripple and Noise 
+3.3V 
+5V 
+12V1/2 
-12V 
+5VSB 